ER-30-300W

Description: 

1:Use ER30 Planar transformer magnetic core,multilayer pcb technique

2:Use for DC/DC module power ,max output power 300W

3:Working frequency :200k∽300K

4:Outline dimension:34.1*30*10mm(Max)

5:withstand voltage between secondary coils:3KVDC

6:Working temperature Range:-40℃-85℃

7:Weight:≤42.5g

According to:                                                               

 

   

 

 

ER-30-300W

 

PART NUMBER

Pri to Sec  Ratio

Primary N1(P1-P5)

Sec

(S1-S2)

N1:N2:AUX

Inductance

( Min)

LeakageInductance

(Max)

DC Resistance

(Max)

TG-ER30T318031

18:3:(2+18)

1.1µH

3.2µH

105mΩ

0.95mΩ

TG-ER30T203081

3:8:N

30µH

0.5µH

2.0mΩ

13mΩ